Implementation of a monitoring system at the prototype level of vital signs: pulse, temperature and oxygen saturation for patients

Authors

DOI:

https://doi.org/10.26439/interfases2021.n014.5168

Keywords:

research methodology, statistical analysis, cloud computing, internet of things

Abstract

The Internet of Things is a digital interconnection between everyday objects and the Internet, which is generally used to improve comfort in daily tasks and optimize business. Thus, it can be integrated into the health world to give it medical applications, being one of the typical application scenarios of the telemedicine service, such as remote medical care. In this way, this article describes the development of a monitoring system for vital signs: pulse, temperature, and oxygen saturation in the blood, which is based on the comparison and selection of components through the research methodology, and its validation through statistical analysis. This monitoring system seeks to be used in the care of patients with home treatments as a compact and low-cost system to provide timely medical information and implement future Cloud Computing and Internet of Things technologies to perform remote monitoring of objective and subjective patient data. In addition, the design and implementation of the mainboard, the selection of biomedical sensors, the preparation of supports and programming are detailed.

Downloads

Download data is not yet available.

Author Biographies

  • Mauricio Alonso Bejarano Reyes, Universidad Nacional de Trujillo, Perú

    Bachiller en Ingeniería Mecatrónica con interés en telemática, aprendizaje automático y visión artificial. Ha trabajado como asesor en gestión y mantenimiento en una empresa de electromecánica y teleinformática. Se graduó en quinto superior en la Universidad Nacional de Trujillo en Ingeniería Mecatrónica.

  • Edgar André Manzano Ramos, Universidad Nacional de Trujillo, Perú

    Magíster en Ingeniería Mecatrónica por la Pontificia Universidad Católica del Perú y bachiller en Ingeniería Electrónica por la Universidad Nacional del Altiplano. Desde el 2017 es profesor en la Universidad Nacional de Trujillo (UNT), donde realizó algunas investigaciones en identificación de sistemas, sistemas de control y procesamiento digital de señales. Actualmente es asesor de la rama estudiantil IEEE de la UNT.

References

Suso-Martí, L., Cuenca-Martínez, F., Arredondo-López, A., y Gil-Martínez, A. (2019). Análisis comparativo de las constantes vitales en pacientes agudos hospitalizados en función de la intensidad de dolor. Revista de la Sociedad Española del Dolor, 26(4), 215-220. https://dx.doi.org/10.20986/resed.2019.3707/2018

Du Gas, B. W. (2000). Tratado de enfermería práctica. (4.ª ed.). McGraw-Hill Interamericana. https://maludice7.com/wp-content/uploads/2019/04/Tratado-de-Enfermeria-Practica-Du-Gas.pdf

EDAN A world of potential. (11 de julio del 2021). iM80: Monitor de Pacientes Multiparamétrico [Archivo PDF]. Monitor paciente Multiparamétrico Edan IM80. https://www.insanexsl.es/producto/monitor-paciente-multiparametrico-edan-im80/

Esquicha Tejada, J. D. (2019). Implementación de un Prototipo de Seguridad Física, para Monitorear Gases, Agua, Temperatura y Humedad en Ambientes Hospitalarios Implementación del prototipo de un sistema de monitoreo de signos vitales por Medio de RASPBERRY PI y BEEBOTTE. [Tesis de segunda especialidad en Auditoria de sistemas de seguridad de información, Universidad Católica de Santa María de Arequipa, Perú]. Repositorio de Tesis UCSM. http://tesis.ucsm.edu.pe/repositorio/handle/UCSM/8823

Seguro social de salud [EsSalud]. (2 de julio del 2020). Pulsioxímetro para uso domiciliario en pacientes con COVID-19 catalogados inicialmente como casos leves y con factores de riesgo. http://www.essalud.gob.pe/ietsi/pdfs/covid_19/RB33_PULSEOXIMETER_14jul2020.pdf

Fundación Cardiovascular de Colombia [FCV]. (26 enero del 2017). Telemedicina beneficia a pacientes pediátricos con enfermedades del corazón. http://www.fcv.org/site/noticias/novedades/380-telemedicina-beneficia-a-pacientes-pediatricos-con-enfermedades-del-corazon

Gonzáles Romero, F. (2019). Diseño e implementación de un pulsioxímetro reflexivo y estudio de su funcionamiento en diferentes zonas del cuerpo. [Trabajo Fin de Grado en Ingeniería de las Tecnologías de Telecomunicación, Universidad de Sevilla, España]. Depósito de Investigación Universidad Sevilla. https://hdl.handle.net/11441/94193

Hailey, D., Roine, R., y Ohinmaa, A. (2002). Systematic review of evidence for the benefits of telemedicine. Journal of Telemedicine and Telecare, 8(1_suppl), 1–7. https://doi.org/10.1258/1357633021937604

Hospital María Auxiliadora. (2010). Manual de procedimientos técnicos de enfermería del departamento de enfermería [Archivo PDF]. https://manualzz.com/doc/25386549/manual-de-procedimientos-tecnicos-del

International Telecommunication Union [ITU]. (2016). Radio Regulations Volume 1 Articles Edition of 2016 [Archivo PDF]. Radio Regulations. http://handle.itu.int/11.1002/pub/80da2b36-en

Maxim Integrated. (19 de enero del 2020). High-Sensitivity Pulse Oximeter and Heart Rate Sensor for Wearable Health. https://datasheets.maximintegrated.com/en/ds/MAX30102.pdf

Mejía Salas, H., y Mejía Suárez, M. (2012). Oximetría de pulso. Revista de la Sociedad Boliviana de Pediatría, 51(2), 149-155. http://www.scielo.org.bo/scielo.php?script=sci_arttextypid=S1024-06752012000200011ylng=esytlng=es

Melexis Microelectronic Integrated Systems. (14 de septiembre del 2006). MLX90614 family: Single and Dual Zone Infra Red Thermometer in TO-39. https://www.sparkfun.com/datasheets/Sensors/Temperature/MLX90614_rev001.pdf

Mercado Libre. (11 de julio del 2021). Monitor de signos vitales de 5 parámetros. https://articulo.mercadolibre.com.pe/MPE-441838079-monitor-de-signos-vitales-de-5-parametrosim-80-_JM#position=29ytype=itemytracking_id=c9c3c8ef-0090-46bf-a59e-c818deaddcca

Ministerio de Energía y Minas [MINEM]. (30 de enero del 2006). Código Nacional de Electricidad [Archivo PDF]. Resolución Ministerial N.° 037-2006-MEM-DM. https://www.gob.pe/institucion/osinergmin/normas-legales/738607-037-2006-mem-dm

Soporte de Minitab® 19. (11 de julio del 2020). Revisión general de t pareada. https://support.minitab.com/es-mx/minitab/19/help-and-how-to/statistics/basic-statistics/how-to/paired-t/before-you-start/overview/

Ministerio de Salud del Perú [MINSA]. (2009). Norma técnica de salud en telesalud. NTS N.º 067-MINSA/DGSP-V.01. http://bvs.minsa.gob.pe/local/MINSA/1428.pdf

Sanmartín Mendoza, P., Ávila Hernández, K., Vilora Núñez, C., y Jabba Molinares, D. (2016). Internet de las cosas y la salud centrada en el hogar. Revista Salud Uninorte, 32(2), 337-351. http://www.scielo.org.co/scielo.php?script=sci_arttextypid=S0120-55522016000200014ylng=enytlng=es

Yauri Rodriguez, R. (2018). Implementación de una red inalámbrica de sensores para el monitoreo remoto de variables fisiológicas en pacientes ambulatorios. [Tesis de Maestría en Ingeniería Biomédica, Universidad Nacional del Callao]. Repositorio Institucional Digital de la Universidad Nacional del Callao. http://hdl.handle.net/20.500.12952/2816

Downloads

Published

2021-12-21

Issue

Section

Research papers

How to Cite

Implementation of a monitoring system at the prototype level of vital signs: pulse, temperature and oxygen saturation for patients. (2021). Interfases, 14(014), 17-40. https://doi.org/10.26439/interfases2021.n014.5168