Implementation of a monitoring system at the prototype level of vital signs: pulse, temperature and oxygen saturation for patients
DOI:
https://doi.org/10.26439/interfases2021.n014.5168Keywords:
research methodology, statistical analysis, cloud computing, internet of thingsAbstract
The Internet of Things is a digital interconnection between everyday objects and the Internet, which is generally used to improve comfort in daily tasks and optimize business. Thus, it can be integrated into the health world to give it medical applications, being one of the typical application scenarios of the telemedicine service, such as remote medical care. In this way, this article describes the development of a monitoring system for vital signs: pulse, temperature, and oxygen saturation in the blood, which is based on the comparison and selection of components through the research methodology, and its validation through statistical analysis. This monitoring system seeks to be used in the care of patients with home treatments as a compact and low-cost system to provide timely medical information and implement future Cloud Computing and Internet of Things technologies to perform remote monitoring of objective and subjective patient data. In addition, the design and implementation of the mainboard, the selection of biomedical sensors, the preparation of supports and programming are detailed.
Downloads
References
Suso-Martí, L., Cuenca-Martínez, F., Arredondo-López, A., y Gil-Martínez, A. (2019). Análisis comparativo de las constantes vitales en pacientes agudos hospitalizados en función de la intensidad de dolor. Revista de la Sociedad Española del Dolor, 26(4), 215-220. https://dx.doi.org/10.20986/resed.2019.3707/2018
Du Gas, B. W. (2000). Tratado de enfermería práctica. (4.ª ed.). McGraw-Hill Interamericana. https://maludice7.com/wp-content/uploads/2019/04/Tratado-de-Enfermeria-Practica-Du-Gas.pdf
EDAN A world of potential. (11 de julio del 2021). iM80: Monitor de Pacientes Multiparamétrico [Archivo PDF]. Monitor paciente Multiparamétrico Edan IM80. https://www.insanexsl.es/producto/monitor-paciente-multiparametrico-edan-im80/
Esquicha Tejada, J. D. (2019). Implementación de un Prototipo de Seguridad Física, para Monitorear Gases, Agua, Temperatura y Humedad en Ambientes Hospitalarios Implementación del prototipo de un sistema de monitoreo de signos vitales por Medio de RASPBERRY PI y BEEBOTTE. [Tesis de segunda especialidad en Auditoria de sistemas de seguridad de información, Universidad Católica de Santa María de Arequipa, Perú]. Repositorio de Tesis UCSM. http://tesis.ucsm.edu.pe/repositorio/handle/UCSM/8823
Seguro social de salud [EsSalud]. (2 de julio del 2020). Pulsioxímetro para uso domiciliario en pacientes con COVID-19 catalogados inicialmente como casos leves y con factores de riesgo. http://www.essalud.gob.pe/ietsi/pdfs/covid_19/RB33_PULSEOXIMETER_14jul2020.pdf
Fundación Cardiovascular de Colombia [FCV]. (26 enero del 2017). Telemedicina beneficia a pacientes pediátricos con enfermedades del corazón. http://www.fcv.org/site/noticias/novedades/380-telemedicina-beneficia-a-pacientes-pediatricos-con-enfermedades-del-corazon
Gonzáles Romero, F. (2019). Diseño e implementación de un pulsioxímetro reflexivo y estudio de su funcionamiento en diferentes zonas del cuerpo. [Trabajo Fin de Grado en Ingeniería de las Tecnologías de Telecomunicación, Universidad de Sevilla, España]. Depósito de Investigación Universidad Sevilla. https://hdl.handle.net/11441/94193
Hailey, D., Roine, R., y Ohinmaa, A. (2002). Systematic review of evidence for the benefits of telemedicine. Journal of Telemedicine and Telecare, 8(1_suppl), 1–7. https://doi.org/10.1258/1357633021937604
Hospital María Auxiliadora. (2010). Manual de procedimientos técnicos de enfermería del departamento de enfermería [Archivo PDF]. https://manualzz.com/doc/25386549/manual-de-procedimientos-tecnicos-del
International Telecommunication Union [ITU]. (2016). Radio Regulations Volume 1 Articles Edition of 2016 [Archivo PDF]. Radio Regulations. http://handle.itu.int/11.1002/pub/80da2b36-en
Maxim Integrated. (19 de enero del 2020). High-Sensitivity Pulse Oximeter and Heart Rate Sensor for Wearable Health. https://datasheets.maximintegrated.com/en/ds/MAX30102.pdf
Mejía Salas, H., y Mejía Suárez, M. (2012). Oximetría de pulso. Revista de la Sociedad Boliviana de Pediatría, 51(2), 149-155. http://www.scielo.org.bo/scielo.php?script=sci_arttextypid=S1024-06752012000200011ylng=esytlng=es
Melexis Microelectronic Integrated Systems. (14 de septiembre del 2006). MLX90614 family: Single and Dual Zone Infra Red Thermometer in TO-39. https://www.sparkfun.com/datasheets/Sensors/Temperature/MLX90614_rev001.pdf
Mercado Libre. (11 de julio del 2021). Monitor de signos vitales de 5 parámetros. https://articulo.mercadolibre.com.pe/MPE-441838079-monitor-de-signos-vitales-de-5-parametrosim-80-_JM#position=29ytype=itemytracking_id=c9c3c8ef-0090-46bf-a59e-c818deaddcca
Ministerio de Energía y Minas [MINEM]. (30 de enero del 2006). Código Nacional de Electricidad [Archivo PDF]. Resolución Ministerial N.° 037-2006-MEM-DM. https://www.gob.pe/institucion/osinergmin/normas-legales/738607-037-2006-mem-dm
Soporte de Minitab® 19. (11 de julio del 2020). Revisión general de t pareada. https://support.minitab.com/es-mx/minitab/19/help-and-how-to/statistics/basic-statistics/how-to/paired-t/before-you-start/overview/
Ministerio de Salud del Perú [MINSA]. (2009). Norma técnica de salud en telesalud. NTS N.º 067-MINSA/DGSP-V.01. http://bvs.minsa.gob.pe/local/MINSA/1428.pdf
Sanmartín Mendoza, P., Ávila Hernández, K., Vilora Núñez, C., y Jabba Molinares, D. (2016). Internet de las cosas y la salud centrada en el hogar. Revista Salud Uninorte, 32(2), 337-351. http://www.scielo.org.co/scielo.php?script=sci_arttextypid=S0120-55522016000200014ylng=enytlng=es
Yauri Rodriguez, R. (2018). Implementación de una red inalámbrica de sensores para el monitoreo remoto de variables fisiológicas en pacientes ambulatorios. [Tesis de Maestría en Ingeniería Biomédica, Universidad Nacional del Callao]. Repositorio Institucional Digital de la Universidad Nacional del Callao. http://hdl.handle.net/20.500.12952/2816
Downloads
Published
Issue
Section
License
Authors who publish with this journal agree to the following terms:
Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under an Attribution 4.0 International (CC BY 4.0) License. that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).
Last updated 03/05/21